Acceptance Mark
NEWS
2014-02-05
20140205 Safety Information
Information products apply UL60950-1, using UL 507 (ZPWV2) recognized DC fan is not

directly
used in the primary circuit

For UL507 (UL CCN: ZPWV2) recognized DC fan following Fig 1, according to UL507

certification requirements
below apply only to such DC fan inside the isolated secondary

voltage circuits (. Follows ILL 1 DC OUTPUT line), the original requirements are as follows :

2.2.15 LOW VOLTAGE COMPONENT FAN – A component fan intended to be used in isolated

secondary circuits and rated a maximum of 30 V rms (42.2 V peak) or 60 V dc.



To such a fan if the product will be designed for use in the primary side (Primary circuit

or transformer-isolated front line) when the non-low-voltage circuit, the test can be

evaluated
in accordance with the non-certified product with the fan mode.

To the power supply (Switching Power Supply) as an example:

DC Fan is directly connected to the primary side of the step-down voltage, and then lock

attached
EARTHED steel, and the bit at the primary side needs to assess the following:

1.
FAN plastic V2 flammability rating to more than.

2. I
nsulation & insulated from the least to meet the BASIC insulation requirements
 
     (FAN
lock attached EARTHED steel).

3.
The need for the VW-1 wire.

4.
Part abnormal test to consider.

5.
UL60950-1, ANNEX B asked to consider the assessment provisions.